Iimveliso
I-Alam ye-MCB kunye noNxibelelwano loNcedo
  • I-Alam ye-MCB kunye noNxibelelwano loNcedoI-Alam ye-MCB kunye noNxibelelwano loNcedo

I-Alam ye-MCB kunye noNxibelelwano loNcedo

Model:DAB7-FL
Thenga i-Alarm ye-CDADA ye-MCB kunye noNxibelelwano oluNcedisayo-imodyuli esebenza kabini kwi-DAB7-63 breakers. Idibanisa abafowunelwa aba-2 (abancedisi + i-alam) kwiyunithi enye ehlangeneyo. Ilungele ukubeka iliso kwimo ekude kunye nokubonakaliswa kwempazamo kwiipaneli. Ukuhlohla ngokulula kwicala lasekhohlo. Njengomzi-mveliso othe ngqo, i-OEM/ixabiso le-wholesale liyafumaneka.

I-CDADA ngumenzi kunye nomthengisi onamava angama-40 +, siye sabona iiprojekthi ezininzi kakhulu apho abaqhubi bephaneli baphoswa yi-breaker ephindwe kabini-de kube kusemva kwexesha. Yingakho siye sayila i-Alarm ye-CDADA MCB kunye noNxibelelwano oluNcedisayo (DAB7-FL): isisombululo esilumkileyo, sokugcina indawo esinika izibonakaliso ezimbini ezibalulekileyo kwimodyuli enye-indawo ye-breaker (ON / OFF) kunye nesizathu sohambo (ukulayisha ngaphezulu / i-short-circuit).

Ingcebiso yethu: Ukuba inkqubo yakho yolawulo ifuna ukwahlula phakathi kwencwadi yokucima kunye nohambo olunempazamo, le yeyona nto kufuneka uyichaze. Abafowunelwa abancedisayo abaqhelekileyo bodwa abanako ukuxela umahluko-kodwa wethu unako.

Mcb Alarm And Auxiliary Contact

Uyilo lweMisebenzi emibini: Imodyuli enye, imiqondiso emibini

I-Alarm ye-CDADA ye-MCB kunye noQhagamshelwano oluNcedisayo luquka abafowunelwa ababini abazimeleyo bokudlulisa kunye nomkhethi ohlakaniphileyo womatshini:

★ Isalathisi emthubi ku-“A”: Bobabini abafowunelwa basebenza njengabancedisi abafowunelwa → bonisa i-MCB ON/OFF

★ Isalathisi emthubi ku-“AL”:

★ Umfowunelwa wasekhohlo = uMncedisi (ON/OFF isimo)

★ Uqhagamshelwano lwasekunene = I-Alarm (isebenza kuphela xa i-MCB ihamba ngenxa yempazamo)

★ Oku kuthetha ukuba ungafaka ucingo:

★ Isibane esiluhlaza ukubonisa "amandla avuliwe"

★ Isibane esibomvu okanye igalelo le-PLC ukuqalisa "i-alarm yempazamo"

★ Konke kwimodyuli yokongeza kwi-DAB7-63 MCB yakho.


IiNgcaciso zobuGcisa

Ipharamitha

Ixabiso

I-MCB ehambelanayo

Uthotho lweCDADA DAB7-63 kuphela (1P–4P)

Uhlobo loQhagamshelwano

Amaqela ama-2 otshintshiselwano (udluliselo) abafowunelwa

Amanqaku oMbane



• I-AC-12: 230V AC, 2A


• I-AC-15: 230V AC, 1A


• DC-12: 11 0V DC, 0.5A

INdawo yokuNyuka

Icala lasekhohlo le-MCB

Ukuhlohla

Ikhuselwe ngeteyiphu enamacala amabini + ikliphu kaloliwe ekhethwayo yeDIN

Ikhonkco lomatshini

Ukudityaniswa kwe-shaft drive ngqo - akukho zixhobo zangaphandle ezifunekayo

Kubalulekile: Esi sixhobo asikwazi ukusetyenziswa ngokuzimeleyo-kufuneka sixhonywe ngqo kwi-DAB7-63 MCB.


Isikhokelo sokuFakelo (Sisuka kwiiNjineli zethu zeNdawo)

★ Landela la manyathelo ngokukhuselekileyo, ukusebenza okuthembekileyo:

★ CIMA isekethe phambi kofakelo.

★ Slayida imodyuli yeDAB7-FL kwicala lasekhohlo le-DAB7-63 MCB ide icofe.

★ Khusela ngetape edibeneyo emacala amabini (ukumelana nokungcangcazela).

★ Qhagamshela iingcingo kwiitheminali ezi-4 (ezi-2 ngeqela ngalinye):

★ Sebenzisa isibini sasekhohlo kumncedisi (isimo)

★ Sebenzisa isibini esifanelekileyo kwi-alam (ukubona uhambo)

★ Cwangcisa umkhethi otyheli ku-"AL" ukuba ufuna i-alarm enempazamo.

★ Uvavanyo: Yikhuphe ngesandla i-MCB-kuphela i-alam yoqhagamshelwano kufuneka itshintshe isimo ngexesha lohambo olunempazamo.

★ Ingcebiso yePro: Bhala iingcingo zakho ngokucacileyo! Amagcisa amaninzi abhidanisa iisignali ezincedisayo kunye ne-alarm ngexesha lokugunyaziswa.


Kufuneka Ukusebenzise nini Oku endaweni yoNxibelelwano oluNcedisayo oluMgangatho?

Imeko

UmNcedisi oMgangatho

I-Alarm yeCDADA + eNcedisayo

Kufuneka ukwazi ukuba i-MCB IVULIWE/IVAMILE na

✅ Ewe

✅ Ewe

Kufuneka uyazi ukuba kutheni ikhubekile (impazamo vs. imanyuwali icinyiwe)

❌ Hayi

✅ Ewe

Iphaneli ene-SCADA/PLC yokubeka iliso ekude

Ulwazi olulinganiselwe

Ukukwazi ukuxilonga ngokupheleleyo

I-alam yomlilo okanye iisekethe ezivaliweyo zokhuseleko

Akwanelanga

Iyahlangabezana neemfuno zekhowudi

Usetyenziso oluqhelekileyo:

★ Iziko leenkcukacha PDU esweni

★ Iibhokisi zokuhlanganisa ilanga

★ Iiphaneli zokulawula ishishini

★ Iinkqubo zolawulo lwezakhiwo (BMS)

★ Elevator okanye iisekethe zokhuseleko HVAC

Imibuzo ebuzwa qho

I-Q1: Ngaba ndingayisebenzisa le nto kwii-MCBs ezingekho zeCDADA?

A1: Hayi. I-DAB7-FL yenziwe ngoomatshini kunye ne-dimensionally yenzelwe kuphela i-CDADA DAB7-63 breakers. Ayizukungena uSchneider, ABB, okanye ii-Siemens MCBs.


Q2: Isebenza njani i-alarm contact?

A2: Ngaphakathi kwe-MCB, i-trip latch mechanism ihamba ngokwahlukileyo ngexesha lohambo lwe-thermal/magnetic fault trip vs. I-DAB7-FL ibona lo mahluko womatshini kwaye isebenze umnxeba we-alamu kuphela ngexesha leempazamo zangempela.


I-Q3: Ngaba ndibafuna bobabini abafowunelwa ngeengcingo?

A3: Akunjalo. Ungasebenzisa kuphela i-alam, i-alamu, okanye zombini-kuxhomekeke kwingqiqo yolawulo lwakho. Imodyuli ikunika ukuguquguquka.


I-Q4: Ngaba ifanelekile kwizicelo zelanga ze-DC?

A4: Ewe! Ngomlinganiselo we-DC-12 we-110V/0.5A, ilungele ukujongwa komtya welanga apho kufuneka ubhaqe iziphene zoluhlu lwePV ukude.


I-Q5: Kutheni ukhetha i-CDADA kwiimpawu eziqhelekileyo?

A5: Kuba sinikezela:

● Ucalucalulo lokwenyani (hayi nje ukujonga indawo)

● Ukuhlanganiswa okungenamthungo kunye ne-DAB7 MCBs-akukho macwecwe e-adapter

● Ukudityaniswa koomatshini abavavanyiweyo basefektri – akukho mdlalo okanye imiqondiso ephosiweyo

● Isalathisi esicacileyo esibonakalayo (iflegi etyheli) yokuqinisekisa indawo

● Izatifikethi zehlabathi (CE, CB, RoHS) kwiiprojekthi ezingenazo iingxaki

Inqaku lokugqibela elivela kwi-CDADA R&D

Kwiinkqubo zombane zanamhlanje, ‘ukucima/ukucima’ akwanelanga—ufuna ubukrelekrele. I-Alarm yethu ye-MCB kunye noNxibelelwano oluNcedisayo lujika i-breaker elula ibe yindawo yokuxilonga, ikunceda ukuba wakhe iipaneli ezihlakaniphile, ezikhuselekileyo. Kwaye ngenxa yokuba yenziwe liqela elifanayo eliyila i-MCB, ufumana intsebenziswano egqibeleleyo-akukho ngqikelelo. " - Iqela leCDADA Product Development

Ukulungele ukuodola? Sinikezela:

● Izaphulelo ezininzi kubakhi bephaneli

● Iiyunithi ezidityaniswe kwangaphambili ze-MCB + DAB7-FL (gcina abasebenzi)

● Imizobo yocingo yasimahla kunye nemizekelo yengqiqo yePLC

Iithegi ezishushu: I-Alarm ye-MCB kunye noNxibelelwano oluNcedisayo, iTshayina, uMvelisi, uMboneleli, iFactory
Thumela uMbuzo
Iinkcukacha zoqhagamshelwano

Vula isiSombululo sakho soMbane esisiSiko kwiiyure ezingama-24!

Kutheni uBuza kuMvelisi okwinqanaba eliphezulu laseTshayina?

✅ Amaxabiso aNgqo kuMzi-mveliso

Sika iindleko zomntu ophakathi! Njengomzi-mveliso oqinisekisiweyo we-ISO 9001 e-China, sihambisa ii-MCCB zeprimiyamu, ii-MCBs, kunye nezaphuli zelanga ze-DC ngamaxabiso akhuphisanayo-exhaswa yi-CE, i-KEMA, kunye nezatifikethi ze-ASTA.

✅ Iminyaka eyi-40+ ye-OEM/ODM yobuGcisa

Guqula ii-casings, iilebhile, okanye i-techs specs ngaphandle komgudu. Iqela lethu le-R&D (i-patent ezingama-60+) liyaphatha:

Amandla ombane angokwezifiso/amanqaku angoku

Ukupakishwa kwegama

Iprototyping ekhawulezayo (iisampulu kwiintsuku ezisi-7)

✅ Izigidi ezi-3+ zeeYunithi zoNyaka

Akukho odolo inkulu kakhulu okanye ingxamisekileyo! Iziqinisekiso zethu zezityalo ezingama-52,400㎡:

◆ Iintsuku ezili-15 zokukhokela iiodolo ezininzi

◆ Ii-MOQ eziguquguqukayo

◆ Uvavanyo olungqongqo lwe-ASTM/UL

✅ Ukuthobela iGlobal, iZero Hassle

Sisombulula imiqobo yokuthumela ngaphandle kumazwe angama-45+:

RoHS/REACH amaxwebhu

Izatifikethi ezingqamene nommandla

Izaphuli zeSolar DC zeeprojekthi eziluhlaza ze-EU

X
Sisebenzisa iikuki ukukunika amava angcono okukhangela, ukuhlalutya ukugcwala kwendawo kunye nokwenza umxholo wakho. Ngokusebenzisa le sayithi, uyavuma ukusebenzisa kwethu ikuki.Umthetho wabucala
YalaYamkela