Iimveliso
Chwetheza iResidual Current Circuit Breaker
  • Chwetheza iResidual Current Circuit BreakerChwetheza iResidual Current Circuit Breaker
  • Chwetheza iResidual Current Circuit BreakerChwetheza iResidual Current Circuit Breaker
  • Chwetheza iResidual Current Circuit BreakerChwetheza iResidual Current Circuit Breaker

Chwetheza iResidual Current Circuit Breaker

Thenga i-CDADA Uhlobo lwe-Residual Current Circuit breaker evela e-Shanghai DADA Electric, sineminyaka engaphezu kwama-40 yamava, ingaba ngumthengisi wakho. I-EN / IEC 61008-1 eqinisekisiweyo, i-2P / 4P, i-16-100A, i-30mA / 100mA iinketho. Ibona i-AC + pulsating DC evuzayo. IP20, iDIN kaloliwe yokunyusela, iyaxhathisa. Ilungele amakhaya anamhlanje kunye neepaneli zorhwebo.

Qinisekisa ukhuseleko olubanzi lomntu kunye nomlilo kwiindawo ezityebileyo ze-elektroniki kunye neCDADA Uhlobo lwe-Residual Current Circuit Breaker (RCCB), sinokunikezela ngexabiso elithe ngqo kwifektri. Ihamba ngaphaya kokufunyanwa kokuvuza okusisiseko kwe-AC-ihamba ngokuthembekileyo kuzo zombini i-sinusoidal AC kunye ne-pulsating DC intsalela yemisinga eyenziwe zizixhobo eziqhelekileyo ezifana neetshaja zefowuni, abaqhubi be-LED, iikhompyuter, kunye nezixhobo eziguqukayo zesantya.

Ifumaneka kwi-2P (1+N) kunye no-4P (3+N) ulungelelwaniso olunomlinganiselo olinganisiweyo ukusuka kwi-16A ukuya kwi-100A kunye nobuthathaka be-10mA, 30mA, 100mA, okanye i-300mA, yenzelwe indawo yokuhlala yangoku, iofisi, kunye nofakelo olulula lwentengiso.

Ngomlinganiselo we-6kA we-short-circuit rating, ukhuseleko lwe-IP20, kunye nezinketho ze-terminal ezimbini (i-lug / pin), i-CDADA Uhlobo lwe-RCCB ludibanisa ukhuseleko, ukuthembeka, kunye noyilo olulungele i-installer-zonke zixhaswa ngokuthotyelwa kwehlabathi.

Type A Residual Current Circuit Breaker

IiNgcaciso eziphambili

Uhlobo lweMveliso: Chwetheza i-RCCB (iNxaxheba yeSekethe yeNdawo eseleyo ngaphandle kokukhuselwa ngokugqithisileyo)
Umgangatho: EN/IEC 61008-1
Iipali: 2P (1+N) okanye 4P (3+N)
Ikalwe ngoku (kwi): 16A, 25A, 32A, 40A, 63A, 80A, 100A
Ulinganiso lombane: 2P:
230V AC 4P:
230/400V AC Ubuthathaka obushiyekileyo (I△n):
10mA, 30mA, 100mA, 300mA UkungaHambi ngoku:
0.5 × I△n Ixesha lohambo e-I△n:
≤ 0.1 isekhondi ISekethe eMfutshane eneMiqathango yangoku (Inc):
6kA Ukwenza kunye noKwaphula isakhono (I₄m):
500A (ye Kwi ≤ 40A)
630A (ye Kwi ≥ 63A)
Impulse Melana neVoltage (Uimp):
6000V Ubushushu bokusebenza:
-25°C ukuya +40°C Isidanga soKhuselo:
IP20 Ukunyuswa:
35mm DIN kaloliwe (EN 60715 iyahambelana) Izikhululo:
Uhlobo lweLug okanye uhlobo lwePin, luxhasa iintambo ukuya kuthi ga kwi-35mm² Isalathisi Esibonakalayo:
Obomvu = IVULIWE (abafowunelwa bavaliwe), Luhlaza = VALIWE (abafowunelwa bavuliwe) Inkqubo yohambo:
Ukukhutshwa kwe-Electromagnetic-ukungakhuseleki kwiinguqu zombane


Kutheni Khetha iCDADA Uhlobo A RCCB?

★  Ichonga iiNgoyi zokuvuza zeLizwe lokwenyani

Ngokungafaniyo nezixhobo ezisisiseko zoHlobo lwe-AC, i-CDADA yohlobo lwe-A iphendula kuzo zombini i-AC kunye ne-pulsating DC-ibalulekile kukhuseleko kumakhaya kunye neeofisi ezizaliswe yi-switch-mode power supply, inverters, kunye neetshaja ze-EV.

★ Akukho Uhambo lwenkathazo

Ukuhluza okukwinqanaba eliphezulu kuqinisekisa ukungakhuseleki kwi-voltage spikes kunye nemisinga edlulayo engenabungozi, ngelixa sisaqinisekisa <0.1s ixesha lohambo ngovakalelo olulinganiselweyo.

★ Sula ubume obubonakalayo

Isalathisi esibomvu / esiluhlaza soqhagamshelwano sivumela ukuqinisekiswa kwangoko kwe-breaker state-ibaluleke kakhulu ngexesha lokugcinwa okanye ukutshekisha ngokukhawuleza.

★ I-Flexible Wiring & High Compatibility

Ixhasa iitheminali zelug okanye zephini kunye neentambo eziyi-35mm², iyenza ihambelane neebhasi zebhasi kunye nezikhondatha eziguqukayo kwiiphaneli zale mihla.

Type A Residual Current Circuit Breaker

★ Iirivet ezimbini ezongezelelweyo

ukonyuka kokuqina kwe-casing kwindawo yokudibanisa i-conductor ngenxa yee-rivets ezimbini ezongezelelweyo kunye ne-faceplate eqinile

Type A Residual Current Circuit Breaker

★ DIN kaloliwe ibamba

Ufakelo olukhawulezayo kunye nokuthembeka okongeziweyo kokungena kwi-DIN kaloliwe ngenxa yelatshi ngokutshixa kabini

Type A Residual Current Circuit Breaker

★ Ukuthotyelwa kweHlabathi, Ixabiso leNdawo

Iqinisekisiwe kwi-IEC/EN 61008-1, ifanelekile kwi-EU, kuMbindi Mpuma, iAfrika, kunye neemarike zaseAsia-kunye namaxabiso akhuphisanayo avela kumenzi othembekileyo waseTshayina.

Type A Residual Current Circuit Breaker

Usetyenziso oluqhelekileyo

Type A Residual Current Circuit BreakerAmakhaya angoku: Iisekethi ezinee-TV, iilaptops, izixhobo zombane zasekhitshini

Type A Residual Current Circuit BreakerIiofisi: Amagumbi e-IT, iintambo zamandla okusebenza

Type A Residual Current Circuit BreakerUkuthengisa: Iinkqubo ze-POS, iimpawu zedijithali, ukukhanya kwe-LED

Type A Residual Current Circuit BreakerAmanqaku okuTjaja e-EV: Umaleko wokhuseleko osisiseko (udityaniswe nesixhobo esisebenza ngokugqithisileyo)

Type A Residual Current Circuit BreakerUfakelo oluHlaziywayo: Iziguquli zelanga ezivelisa ukuvuza okuvuzayo kwe-DC

Type A Residual Current Circuit Breaker

FAQ

I-Q1: Uthini umahluko phakathi koHlobo A kunye noHlobo lwe-AC RCDs?

I-A1: Uhlobo lwe-AC lubona kuphela ukuvuza okugudileyo kwe-sinusoidal AC. Uhlobo A lubhaqa zombini i-AC kunye ne-pulsating DC (umzekelo, kwii-rectifiers kwiitshaja zefowuni, abaqhubi be-LED, okanye oomatshini bokuhlamba). Kuyo nayiphi na isekethe ene-electronics, Uhlobo A lufunwa ngeekhowudi zombane zanamhlanje.


I-Q2: Ngaba i-30mA Uhlobo lwe-RCD lwanele ukukhuselwa komntu?

A2: Ewe. I-30mA ngumgangatho oqhelekileyo wokhuseleko lokothuka olusindisa ubomi ngokwe-IEC nganye. Udidi lwe-CDADA lwe-A luqinisekisa ukuba lusebenza nokuba impazamo ibandakanya amacandelo e-DC-oyenza ikhuseleke kunoHlobo lwe-AC kwiimeko zangempela zehlabathi.


I-Q3: Ngaba le RCCB ibonelela ngokugqithiswa okanye ukhuseleko lwesekethe emfutshane?

I-A3: Hayi. Le yi-RCCB ecocekileyo (akukho khuselo olugqithisiweyo). Kufuneka isetyenziswe kuthotho kunye ne-MCB okanye i-fuse ukukhusela ukugqithiswa kunye neesekethe ezimfutshane.


I-Q4: Ngaba ndingayisebenzisa kwi-TT systeming system?

I-A4: Ewe-Uhlobo lwe-Residual Current Circuit Breakers lusetyenziswa ngokuqhelekileyo kwiinkqubo ze-TT, ngakumbi nge-100mA okanye i-300mA yokukhusela umlilo kumntu ongenayo, kunye ne-30mA kwiisekethe zokugqibela.


I-Q5: Kutheni ukhetha i-CDADA ngaphezu kwezinye iintlobo ze-A?

A5: CDADA inikeza:

● Inyaniso ye-IEC 61008-1 yokuthobela iingxelo zovavanyo

● Iinketho ezimbini zetheminali (ilugi/iphini) kwiingcingo eziguquguqukayo

● Imo yoqhagamshelwano enekhowudi yombala (obomvu/luhlaza)

● Uyilo lwe-Surge-immune-akukho hambo lobuxoki

● Ukulungelelaniswa kwe-OEM: amaxabiso amaninzi, amaxwebhu esiNgesi, isampuli ngokukhawuleza

Type A Residual Current Circuit Breaker



Iithegi ezishushu: Chwetheza i-A Residual yangoku yeSekethe Breaker, eTshayina, uMvelisi, uMboneleli, iFactory
Thumela uMbuzo
Iinkcukacha zoqhagamshelwano

Vula isiSombululo sakho soMbane esisiSiko kwiiyure ezingama-24!

Kutheni uBuza kuMvelisi okwinqanaba eliphezulu laseTshayina?

✅ Amaxabiso aNgqo kuMzi-mveliso

Sika iindleko zomntu ophakathi! Njengomzi-mveliso oqinisekisiweyo we-ISO 9001 e-China, sihambisa ii-MCCB zeprimiyamu, ii-MCBs, kunye nezaphuli zelanga ze-DC ngamaxabiso akhuphisanayo-exhaswa yi-CE, i-KEMA, kunye nezatifikethi ze-ASTA.

✅ Iminyaka eyi-40+ ye-OEM/ODM yobuGcisa

Guqula ii-casings, iilebhile, okanye i-techs specs ngaphandle komgudu. Iqela lethu le-R&D (i-patent ezingama-60+) liyaphatha:

Amandla ombane angokwezifiso/amanqaku angoku

Ukupakishwa kwegama

Iprototyping ekhawulezayo (iisampulu kwiintsuku ezisi-7)

✅ Izigidi ezi-3+ zeeYunithi zoNyaka

Akukho odolo inkulu kakhulu okanye ingxamisekileyo! Iziqinisekiso zethu zezityalo ezingama-52,400㎡:

◆ Iintsuku ezili-15 zokukhokela iiodolo ezininzi

◆ Ii-MOQ eziguquguqukayo

◆ Uvavanyo olungqongqo lwe-ASTM/UL

✅ Ukuthobela iGlobal, iZero Hassle

Sisombulula imiqobo yokuthumela ngaphandle kumazwe angama-45+:

RoHS/REACH amaxwebhu

Izatifikethi ezingqamene nommandla

Izaphuli zeSolar DC zeeprojekthi eziluhlaza ze-EU

X
Sisebenzisa iikuki ukukunika amava angcono okukhangela, ukuhlalutya ukugcwala kwendawo kunye nokwenza umxholo wakho. Ngokusebenzisa le sayithi, uyavuma ukusebenzisa kwethu ikuki.Umthetho wabucala
YalaYamkela