Iimveliso
Uhlobo lwe-AC lwe-Circuit Breaker kunye neNxalenye yokuSebenza ngoku
  • Uhlobo lwe-AC lwe-Circuit Breaker kunye neNxalenye yokuSebenza ngokuUhlobo lwe-AC lwe-Circuit Breaker kunye neNxalenye yokuSebenza ngoku
  • Uhlobo lwe-AC lwe-Circuit Breaker kunye neNxalenye yokuSebenza ngokuUhlobo lwe-AC lwe-Circuit Breaker kunye neNxalenye yokuSebenza ngoku

Uhlobo lwe-AC lwe-Circuit Breaker kunye neNxalenye yokuSebenza ngoku

Model:DAM1L
I-CDADA, umenzi oqeqeshiweyo oneminyaka eyi-40 + yamava, unokubonelela ngekhwalithi ephezulu ye-AC TYPE Circuit Breaker kunye ne-Residual Current Operation (DAM1L). I-4P, i-10-500A, i-CE/CB/SEMKO iqinisekisiwe. Yinyani yohlobo lwe-AC CBR yokuvuza kwe-sinusoidal kuphela. Ilungele indawo yokuhlala kunye neshishini lomlilo / ukhuseleko lomntu.

Hlangana nemigangatho yokhuseleko yehlabathi kunye ne-CDADA DAM1L AC Type Circuit Breaker kunye neResidual Current Operation i-MCCB yomhlaba evuzayo ephezulu eyenziwe ngu-Shanghai DADA Electric CO., LTD. ukhuseleko oluthembekileyo kwiimpazamo zomhlaba we-sinusoidal AC kuphela (nge-IEC 60755).

Eyilwe njenge-4P i-molded case breaker ilinganiswe kwi-10A ukuya kwi-500A kwi-400V / 415V, idibanisa ukugqithiswa, i-short-circuit, kunye nokukhusela ngoku okushiyekileyo kwiyunithi enye. Ukuqinisekiswa kwi-CE, CB, kunye ne-SEMKO, i-DAM1L ifanelekile kwizicelo apho ukukhangela ukuvuza okucocekileyo kwe-AC kwanele njengendawo yokuhlala eqhelekileyo, iisekethe zokukhanyisa, okanye imithwalo yemoto ngaphandle kwe-electronic drives.

Nge-adjustable I△n (30mA-1000mA), i-electronics multi-phase powered powered (ukusebenza phantsi ukuya kwi-50V), kunye nokuhlukana okuqinileyo kwe-arc, inikezela ukusebenza okungaphumeleliyo kwizakhiwo, iitonela kunye neziseko-ngelixa ithobela ngokungqongqo iimfuno ze-ACD ze-RCD.

AC Type Circuit Breaker with Residual Current Operation

IiNgcaciso eziphambili

Uhlobo lweMveliso: UHLOBO lwe-AC olushiyekileyo lweSaphuli seSekethe yangoku (i-RCBO/MCCB idityanisiwe)
Uluhlu lweemodeli: I-DAM1L
Iipali: 4P (esemgangathweni)
Ikalwe ngoku (kwi): 10A - 500A
Ulinganiso lombane: 400V / 415V AC, 50Hz
I-Insulation Voltage (Ui): 400V (<160A), 690V (>250A)
Uhlobo Lwangoku olushiyekileyo: I-AC TYPE - iphendula kuphela kwi-smooth sinusoidal AC ukuvuza
I△n Iisetingi: 30mA, 100mA, 300mA, 500mA, 1000mA (enokulungiswa kwisiza)
Ixesha Lohambo: Ngoko nangoko okanye ilibaziseko (0.05s–0.8s, kuxhomekeke kulungiselelo)
Ukwaphulwa kwesakhono: Iintlobo ze-B/S/H (ukuya kuthi ga kwi-high-breaking>160A)
Iziqinisekiso: CE, CB, SEMKO


Ezona mpawu:

★ I-multi-phase powered RCD circuit → isebenza kwi-≥50V

★ Push-to-test iqhosha

★ Yahlula abafowunelwa abaphambili kunye ne-arcing

★ Uhambo lwemagnethi olunokulungiswa (0.8–1.0×In)

★ olomeleleyo EMI immunity

★ Inkxaso epheleleyo ye-accessory (uhambo lwe-shunt, abafowunelwa be-aux, umqheba wokujikeleza)


Kutheni Khetha i-CDADA AC TYPE CBR?

★ Ukuthotyelwa kweNyaniso ye-AC-Type

Ngokungafaniyo nezixhobo "zendalo yonke" ye-A-type, i-CDADA ye-AC-uhlobo lwe-CBR ilungiselelwe kuphela ukuvuza kwe-sinusoidal AC-ukubonelela ngeendleko eziphezulu zeendleko apho imithwalo ye-elektroniki (umzekelo, i-VFDs, i-SMPS) ingekho.

★ Ukungaphumeleli-uKhuseleko loyilo lwaMandla

I-electronics ye-RCD idonsa amandla kuzo zonke izigaba, iqinisekisa ukusebenza nangexesha lokulahleka kwesigaba esisodwa okanye ukungabikho kwamandla obunzima-inzuzo ebalulekileyo ngaphezu kwabakhuphisana besigaba esisodwa.

★ Iindima ezimbini zoKhuseleko

● 30mA: Idibana ne-IEC yokukhusela ukothuka komntu

● 100mA–1000mA: Ikhusela ukugquma-ukusilela kwimililo kwiintambo kunye neebhokisi zokuhlangana

★ Ukhuseleko olunokulungiswa kwibala

Tune uvakalelo kunye nokulibaziseka kwexesha ukuze utshatise iimeko zofakelo-ukuphepha iihambo eziphazamisayo ngelixa ugcina ukuthotyelwa kwekhowudi.

★ I-Industrial-Grade Integration

Idibanisa i-MCCB kunye ne-RCD kwiyunithi enye etywiniweyo-ukugcina indawo, ukunciphisa iimpazamo ze-wiring, kunye nokuqinisekisa ukulungelelaniswa okugqibeleleyo.

★ Yamkelwe kwihlabathi jikelele

Nge-CE, CB, kunye ne-SEMKO, ivunyiwe ukuba isetyenziswe kulo lonke elaseYurophu, kuMbindi Mpuma, e-Afrika, nase-Asia-ilungele abakhi bamaphaneli abajolise kumazwe angaphandle.

★ Iimveliso zethu zibonelelwe ngeeprojekthi zegridi yombane, imizi-mveliso, izakhiwo zorhwebo, kunye neeprojekthi zeziseko ezingundoqo kumazwe amaninzi.

AC Type Circuit Breaker with Residual Current Operation

★ Sityala imali ngokuqhubekayo kwi-R&D, sibeka iliso kwimigangatho yehlabathi kunye nentsingiselo yemarike, kwaye sisebenzisana neengcaphephe zeshishini ukuphucula ipotfoliyo yemveliso yethu.


Usetyenziso oluqhelekileyo

AC Type Circuit Breaker with Residual Current OperationIzakhiwo zokuhlala: Iiphaneli eziphambili okanye iisekethe ezincinci (izibane, iisokethi) ngaphandle kombane

AC Type Circuit Breaker with Residual Current OperationIzibane zoRhwebo: Iisekethe zesilingi zeofisi, izibane zepaseji

AC Type Circuit Breaker with Residual Current OperationImithwalo yeMoto yesiNtu: Iimpompo, iifeni, iicompressors (ezingaqhutywanga yi-VFD)

AC Type Circuit Breaker with Residual Current OperationIziseko zophuhliso: Izibane zetonela, iikhabhathi zasezitalatweni, amagumbi omatshini wokuphakamisa umgangatho

IiProjekthi eziBalulekileyo kwiindleko: Apho ii-RCD zohlobo lwe-A zingafunekiyo kwaye zichazwe ngokugqithisileyo


FAQ

I-Q1: Ithetha ukuthini i-"AC TYPE" kwisixhobo sangoku esishiyekileyo?

I-A1: I-AC TYPE CBRs iphendula kuphela kwi-smooth, sinusoidal alternating residual currents (umzekelo, ukusuka kwi-insulation eyonakalisiweyo kwii-heaters okanye ii-motor). Abayiboni i-DC ejikelezayo kwizinto zombane ezifana neetshaja zefowuni okanye abaqhubi be-LED. Sebenzisa u-A-uhlobo ukuba imithwalo enjalo ikhona.


Q2: Ndingayisebenzisa le AC CBR 63A kwisekethe yesokethi yasekhaya?

I-A2: Kuphela ukuba isekethe ayinazo izixhobo zombane (umzekelo, imithwalo ecocekileyo yokumelana nezibane ze-incandescent okanye iiketile zesidala). Kumakhaya anamhlanje anomabonakude, iilaptops, okanye izibane ze-LED, khetha i-A-type RCD endaweni yoko.


Q3: Kutheni ndingakhetha uhlobo lwe-AC kunohlobo lwe-A?

A3: Ixabiso eliphantsi kunye nokungakhuseleki okuphezulu kukukhubekisa okungeyonyani kwimeko ye-AC kuphela. Ukuba isixokelelwano sakho asinazo izinto zokulungisa, iziguquli, okanye izixhobo zombane zendlela yokutshintsha, uhlobo lwe-AC lwanele kwaye lunoqoqosho ngakumbi.


I-Q4: Ngaba iyasebenza ukuba isigaba esinye siyasilela?

A4: Ewe! Isekethe ye-RCD inikwe amandla ngokubonelela ngezigaba ezininzi, ngoko ihlala isebenza nangexesha lokulahleka kwesigaba okanye ukuhla kwe-voltage ukuya kwi-50V-ukuqinisekisa ukukhuselwa kokuvuza okuqhubekayo.


I-Q5: Kutheni ukhetha i-CDADA ye-AC Type Circuit Breaker nge-Residual Current Operation?

A5: CDADA inikeza:

● I-IEC ye-IEC 60755 yoyilo oluhambelana nohlobo lwe-AC

● I-MCCB edibeneyo + ne-RCD kwiyunithi enye (akukho miba yokuhambelana)

● Ii-electronics ezixhaswe ngamanqanaba amaninzi ukwenzela ukuthembeka

● Ukulungelelaniswa kwendawo ye-I△n kunye nokulibaziseka kwexesha

● Iziqinisekiso zehlabathi (CE/CB/SEMKO) ngexabiso le-OEM-friendly

Iithegi ezishushu: Uhlobo lwe-AC lwe-Circuit Breaker ngokuSebenza ngoku Okushiyekileyo, eTshayina, uMvelisi, uMboneleli, iFactory
Thumela uMbuzo
Iinkcukacha zoqhagamshelwano

Vula isiSombululo sakho soMbane esisiSiko kwiiyure ezingama-24!

Kutheni uBuza kuMvelisi okwinqanaba eliphezulu laseTshayina?

✅ Amaxabiso aNgqo kuMzi-mveliso

Sika iindleko zomntu ophakathi! Njengomzi-mveliso oqinisekisiweyo we-ISO 9001 e-China, sihambisa ii-MCCB zeprimiyamu, ii-MCBs, kunye nezaphuli zelanga ze-DC ngamaxabiso akhuphisanayo-exhaswa yi-CE, i-KEMA, kunye nezatifikethi ze-ASTA.

✅ Iminyaka eyi-40+ ye-OEM/ODM yobuGcisa

Guqula ii-casings, iilebhile, okanye i-techs specs ngaphandle komgudu. Iqela lethu le-R&D (i-patent ezingama-60+) liyaphatha:

Amandla ombane angokwezifiso/amanqaku angoku

Ukupakishwa kwegama

Iprototyping ekhawulezayo (iisampulu kwiintsuku ezisi-7)

✅ Izigidi ezi-3+ zeeYunithi zoNyaka

Akukho odolo inkulu kakhulu okanye ingxamisekileyo! Iziqinisekiso zethu zezityalo ezingama-52,400㎡:

◆ Iintsuku ezili-15 zokukhokela iiodolo ezininzi

◆ Ii-MOQ eziguquguqukayo

◆ Uvavanyo olungqongqo lwe-ASTM/UL

✅ Ukuthobela iGlobal, iZero Hassle

Sisombulula imiqobo yokuthumela ngaphandle kumazwe angama-45+:

RoHS/REACH amaxwebhu

Izatifikethi ezingqamene nommandla

Izaphuli zeSolar DC zeeprojekthi eziluhlaza ze-EU

X
Sisebenzisa iikuki ukukunika amava angcono okukhangela, ukuhlalutya ukugcwala kwendawo kunye nokwenza umxholo wakho. Ngokusebenzisa le sayithi, uyavuma ukusebenzisa kwethu ikuki.Umthetho wabucala
YalaYamkela